1. Indonesia
  2. All 3M Products
  3. Electrical
  4. Power Cable Connectors
  5. Power Cable Terminations
  6. 3M™ Cold Shrink QT-III 3/C Termination Kit 7622-S-2-3G, Tape/Wire/UniShield®, 5-15 kV, Insulation OD 0.70-0.92 in, 3/kit

3M™ Cold Shrink QT-III 3/C Termination Kit 7622-S-2-3G, Tape/Wire/UniShield®, 5-15 kV, Insulation OD 0.70-0.92 in, 3/kit

  • 3M ID 7000132898
  • UPC 00054007436812

Provides a void-free seal to tape shield, wire shield and UniShield® power cables

High dielectric-constant material regulates the distribution of electric field stress

Suitable for outdoor applications

View more details

Details

Highlights
  • Provides a void-free seal to tape shield, wire shield and UniShield® power cables
  • High dielectric-constant material regulates the distribution of electric field stress
  • Suitable for outdoor applications
  • Termination has 0.70 to 0.92-in insulation O.D. and 3.30-in maximum cable O.D
  • Accommodates wire sizes of 4/0 AWG to 350 kcmil at 5kV 100%, 3/0 AWG to 350 kcmil at 5kV 133%, 3/0 AWG to 350 kcmil at 8 kV 100%/133%, 1/0 to 4/0 AWG at 15kV 100%, 2 to 3/0 AWG at 15kV 133%
  • Integrated design allows for easier installation, while sealing compounds provide constant radial pressure
  • Withstands voltages of 5 to 35kV and is 110 kV BIL-rated
  • Includes a 3-phase, cold shrink termination
  • IEEE Approved

3M™ Cold Shrink QT-III 7600-S-3G Series Termination Kit includes a skirted, 3-phase termination. It ensures a pliable, tight seal for tape shield, wire shield and UniShield® power cables. The conjunction of high dielectric-constant material and sealing compounds allows the termination to withstand voltages of 5 to 35kV.

3M™ Cold Shrink QT-III 7600-S-3G Series Termination Kit is designed for terminating medium voltage, 3-conductor cables with internal ground wires. The UV stable, track-resistant and hydrophobic construction makes the termination suitable for outdoor applications. The lower surface stress, high dielectric-constant material offers an optimized BIL performance while ensuring a leak-proof, compact fit. IEEE Approved.Conductor Size Range for· 5 kV-100% (133%): 4/0 AWG-350 kcmil (3/0 AWG-350 kcmil)· 8 kV-100% (133%): 3/0 AWG-350 kcmil (3/0 AWG-350 kcmil)· 15 kV-100% (133%): 1/0-4/0 AWG (2-3/0 AWG)

Typical Properties

BIL

110 kV

Brands

3M™

Breakout Boot

Yes

Cable Insulation Outside Diameter Range (metric)

17.8-23.4 mm

Case Quantity

1

Indoor/Outdoor

Outdoor Skirted

Insulation Level

100%, 133%

Insulation Outer Diameter (metric)

17.78 mm, 18.034 mm, 18.288 mm, 18.542 mm, 18.796 mm, 19.05 mm, 19.304 mm, 19.558 mm, 19.812 mm, 20.066 mm, 20.32 mm, 20.574 mm, 20.828 mm, 21.082 mm, 21.336 mm, 21.59 mm, 21.844 mm, 22.098 mm, 22.352 mm, 22.606 mm, 22.86 mm, 23.114 mm, 23.368 mm

Insulation Rejacketing

Yes

Lug/Stem Connector Included in Kit

No

Maximum Cable Outside Diameter (metric)

83.8 mm

Number of Conductors

3

Number of Skirts

2

Product Series

7600-S-3G

Shielding Type

Tape Shield, UniShield®, Wire Shield

Voltage

5 kV, 8 kV, 15 kV

Voltage Application

Medium Voltage