1. Indonesia
  2. All 3M Products
  3. Electrical
  4. Power Cable Connectors
  5. Power Cable Terminations
  6. 3M™ Cold Shrink QT-III Three Conductor Cable Termination Kit 7693-S-4-3W, Tape, Wire and UniShield®, 25/28 kV, 0.92-1.18 in (23.4-30.0 mm) Cable Insul. O.D., 3 terminations/kit

3M™ Cold Shrink QT-III Three Conductor Cable Termination Kit 7693-S-4-3W, Tape, Wire and UniShield®, 25/28 kV, 0.92-1.18 in (23.4-30.0 mm) Cable Insul. O.D., 3 terminations/kit

  • 3M ID 7000031628
  • UPC 00054007047537

Provides a void-free seal to tape shield, wire shield and UniShield® power cables

High dielectric-constant material regulates the distribution of electric field stress

Suitable for outdoor applications

View more details

Details

Highlights
  • Provides a void-free seal to tape shield, wire shield and UniShield® power cables
  • High dielectric-constant material regulates the distribution of electric field stress
  • Suitable for outdoor applications
  • Termination has 0.92 to 1.18-in insulation O.D
  • Accommodates wire sizes of 500 to 750 kcmil at 5kV, 400 to 600 kcmil at 8 kV, 120 to 185 mm² at 15kV, 2/0 AWG to 250 kcmil at 25/28 kV
  • Integrated design allows for easier installation in limited spaces, while sealing compounds provide constant radial pressure
  • Withstands voltages of 5 to 35kV and is 150 kV BIL-rated
  • Includes a 4-skirt, 3-phase, cold shrink termination
  • JIS, IEC and AEIC Approved

3M™ Cold Shrink QT-III 7600-S-3W Series Termination Kit includes a skirted, 3-phase termination. It ensures a pliable, tight seal for tape shield, wire shield and UniShield® power cables. The conjunction of high dielectric-constant material and sealing compounds allows the termination to withstand voltages of 5 to 35kV.

3M™ Cold Shrink QT-III 7600-S-3W Series Termination Kit is designed for terminating medium voltage, 3/C-shielded cables without ground wires. The track-resistant, silicone rubber construction makes the termination suitable for outdoor applications. The lower surface stress, high dielectric-constant material offers an optimized BIL performance while ensuring a leak-proof, compact fit. The short installed length of the termination makes it ideal for use in compact spaces, comprising motors, starters, switchgear, variable speed drives, transformers and other similar connections. JIS, IEC and AEIC Approved.Conductor Size Range for· 5 kV: 500-750 kcmil· 8 kV: 400-600 kcmil· 15 kV: 250-450 kcmil · 25/28 kV: 2/0 AWG-250 kcmil

Typical Properties

BIL

150 kV

Brands

3M™

Breakout Boot

Yes

Cable Insulation Outside Diameter Range (metric)

23.4-30.0 mm

Case Quantity

1

Indoor/Outdoor

Outdoor Skirted

Insulation Level

100%, 133%

Insulation Outer Diameter (metric)

23.368 mm, 23.622 mm, 23.876 mm, 24.13 mm, 24.384 mm, 24.638 mm, 24.892 mm, 25.146 mm, 25.4 mm, 25.654 mm, 25.908 mm, 26.162 mm, 26.416 mm, 26.67 mm, 26.924 mm, 27.178 mm, 27.432 mm, 27.686 mm, 27.94 mm, 28.194 mm, 28.448 mm, 28.702 mm, 28.956 mm, 29.21 mm, 29.464 mm, 29.718 mm, 29.972 mm

Insulation Rejacketing

Yes

Lug/Stem Connector Included in Kit

No

Number of Conductors

3

Number of Skirts

4

Product Series

7600-S-3W

Shielding Type

UniShield®, Wire Shield, Tape Shield

Voltage

5 kV, 8 kV, 15 kV, 25 kV

Voltage Application

Medium Voltage