1. Indonesia
  2. All 3M Products
  3. Electrical
  4. Power Cable Connectors
  5. Power Cable Terminations
  6. 3M™ Cold Shrink QT-II Indoor Termination Kit 5623K, Tape, Wire and UniShield®, 5-15 kV, 0.56-0.87 in (14-22 mm) Cable Insul. O.D., 3 terminations/kit

3M™ Cold Shrink QT-II Indoor Termination Kit 5623K, Tape, Wire and UniShield®, 5-15 kV, 0.56-0.87 in (14-22 mm) Cable Insul. O.D., 3 terminations/kit

  • 3M ID 7000005936
  • UPC 00054007122524

Provides a void-free seal to tape shield, wire shield and UniShield® power cables

High dielectric-constant material regulates the distribution of electric field stress

Suitable for indoor applications

View more details

Details

Highlights
  • Provides a void-free seal to tape shield, wire shield and UniShield® power cables
  • High dielectric-constant material regulates the distribution of electric field stress
  • Suitable for indoor applications
  • Termination has 0.56 to 0.87-in insulation O.D
  • Accommodates wire sizes of 2/0 AWG to 250 kcmil at 5kV 100%, 1/0 to 4/0 AWG at 5kV 133%/8 kV 100%, 1 to 3/0 AWG at 8 kV 133%, 4 to 2/0 AWG at 15kV 100%, 4 to 1 AWG at 15kV 133%
  • Non-tracking, molded, silicone rubber insulation offers durability
  • Withstands voltages of 5 to 15kV and is 110 kV BIL-rated
  • Includes three 1-piece, single-phase, cold shrink terminations
  • IEEE Standard 48 Class 1 Approved for weather-protected applications

3M™ Cold Shrink QT-II 5620K Series Termination Kit includes three 1-piece, non-skirted single-phase terminations. It ensures a pliable, tight seal for tape shield, wire shield and UniShield® power cables. The conjunction of high dielectric-constant material and silicone rubber insulation allows the termination to withstand voltages of 5 to 15kV.

3M™ Cold Shrink QT-II 5620K Series Termination Kit is designed for terminating medium voltage, solid dielectric-shielded cables in indoor applications. When the terminal's core is unwound, it shrinks over the cable and ensures a leak-proof, ideal fit. The track-resistant, silicone rubber insulation of the termination offers a long-lasting service life. IEEE Standard 48 Class 1 Approved for weather-protected applications.Conductor Size Range for· 5 kV (100%): 2/0 AWG-250 kcmil· 5 kV (133%): 1/0-4/0 AWG · 8 kV (100%): 1/0-4/0 AWG· 8 kV (133%): 1-3/0 AWG · 15 kV (100%): 4-2/0 AWG · 15 kV (133%): 4-1 AWG

Typical Properties

BIL

110 kV

Brands

3M™

Breakout Boot

No

Cable Insulation Outside Diameter Range (metric)

14.2-22.1 mm

Indoor/Outdoor

Indoor Non-skirted

Insulation Level

100%, 133%

Insulation Outer Diameter (metric)

14.224 mm, 14.478 mm, 14.732 mm, 14.986 mm, 15.24 mm, 15.494 mm, 15.748 mm, 16.002 mm, 16.256 mm, 16.51 mm, 16.764 mm, 17.018 mm, 17.272 mm, 17.526 mm, 17.78 mm, 18.034 mm, 18.288 mm, 18.542 mm, 18.796 mm, 19.05 mm, 19.304 mm, 19.558 mm, 19.812 mm, 20.066 mm, 20.32 mm, 20.574 mm, 20.828 mm, 21.082 mm, 21.336 mm, 21.59 mm, 21.844 mm, 22.098 mm

Insulation Rejacketing

No

Lug/Stem Connector Included in Kit

No

Number of Conductors

1

Product Series

5620K

Shielding Type

UniShield®, Wire Shield, Tape Shield

Voltage

5 kV, 8 kV, 15 kV