1. Indonesia
  2. All 3M Products
  3. Electrical
  4. Power Cable Connectors
  5. Power Cable Terminations
  6. 3M™ Cold Shrink QT-II Indoor Termination Kit 5622K, Tape, Wire and UniShield®, 5-8 kV, 0.44-0.65 in (1-17 mm) Cable Insul. O.D., 3 terminations/kit

3M™ Cold Shrink QT-II Indoor Termination Kit 5622K, Tape, Wire and UniShield®, 5-8 kV, 0.44-0.65 in (1-17 mm) Cable Insul. O.D., 3 terminations/kit

  • 3M ID 7000005935
  • UPC 00054007122517

Provides a void-free seal to tape shield, wire shield and UniShield® power cables

High dielectric-constant material regulates the distribution of electric field stress

Suitable for indoor applications

View more details

Details

Highlights
  • Provides a void-free seal to tape shield, wire shield and UniShield® power cables
  • High dielectric-constant material regulates the distribution of electric field stress
  • Suitable for indoor applications
  • Termination has 0.44 to 0.65-in insulation O.D
  • Accommodates wire sizes of 2 to 2/0 AWG at 5kV 100%, 4 to 1/0 AWG at 5kV 133%/8 kV 100%, 6 to 1 AWG at 8 kV 133%
  • Non-tracking, molded, silicone rubber insulation offers durability
  • Withstands voltages of 5 to 15kV and is 110 kV BIL-rated
  • Includes three 1-piece, single-phase, cold shrink terminations
  • IEEE Standard 48 Class 1 Approved for weather-protected applications

3M™ Cold Shrink QT-II 5620K Series Termination Kit includes three 1-piece, non-skirted single-phase terminations. It ensures a pliable, tight seal for tape shield, wire shield and UniShield® power cables. The conjunction of high dielectric-constant material and silicone rubber insulation allows the termination to withstand voltages of 5 to 15kV.

3M™ Cold Shrink QT-II 5620K Series Termination Kit is designed for terminating medium voltage, solid dielectric-shielded cables in indoor applications. When the terminal's core is unwound, it shrinks over the cable and ensures a leak-proof, ideal fit. The track-resistant, silicone rubber insulation of the termination offers a long-lasting service life. IEEE Standard 48 Class 1 Approved for weather-protected applications.Conductor Size Range for· 5 kV (100%): 2-2/0 AWG · 5 kV (133%): 4-1/0 AWG · 8 kV (100%): 4-1/0 AWG · 8 kV (133%): 6-1 AWG

Typical Properties

BIL

110 kV

Brands

3M™

Breakout Boot

No

Cable Insulation Outside Diameter Range (metric)

11.2-16.5 mm

Indoor/Outdoor

Indoor Non-skirted

Insulation Level

100%, 133%

Insulation Outer Diameter (metric)

11.176 mm, 11.43 mm, 11.684 mm, 11.938 mm, 12.192 mm, 12.446 mm, 12.7 mm, 12.954 mm, 13.208 mm, 13.462 mm, 13.716 mm, 13.97 mm, 14.224 mm, 14.478 mm, 14.732 mm, 14.986 mm, 15.24 mm, 15.494 mm, 15.748 mm, 16.002 mm, 16.256 mm, 16.51 mm

Insulation Rejacketing

No

Lug/Stem Connector Included in Kit

No

Number of Conductors

1

Product Series

5620K

Shielding Type

Tape Shield, UniShield®, Wire Shield

Voltage

5 kV, 8 kV